New Volt Amp

120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4

120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4
120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4

120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4   120/240 Volt kWh Meter, 100 Amp with 2 Internal CTs - Need 2 CTs for USA Power #4

120/240 Volt kWh Meter, 100 Amp w/ 2 Internal CTs -- Need 2 CTs for USA Power #4. Single Phase, Pass-Through kWh Meter, 2 or 3-Wire, 120V up to 120/240V.

This new meter model has been designed to replace both of our legacy single phase pass-though kWh meters (EKM-25IDS and EKM-15IDS). The EKM-25XDSE replaces the functionality of both of these legacy meters and offers a number of additional improvements to their designs.

Compact and very easy to install. Wires pass through 13.7mm (0.5 inch) diameter tubes in the meter body -- Will accept 22 AWG - 1 AWG wire. There are two piercing screws that pierce the wires that pass through the meter. The meter comes with two sets of bushings for medium and small wire diameter wires, which keep the wires centered so the piercing screws have no trouble engaging the conductor.

The upside-down teardrop shape of the tubes also serves to keep the wires centered. Single Phase 120/240V 3-Wire (2 hots, 1 neutral): In this configuration both hot wires pass through the body of the meter. The piercing screws are used to pierce the wire insulation to provide the meter with a voltage reference for each line. There is also a port on the meter for a neutral reference.

The meter will function without this connection (at 1% accuracy) but it will be 0.5% accurate with the neutral connection. Single Phase 120V or 208-240V 2-Wire (2 hots): As described above, the meter is designed to meter single phase electrical systems that don't have a neutral available. Both hot wires pass though the body of the meter and the piercing screws are used to pierce the wire insulation to provide voltage references to the meter. Single Phase 120V or 208-240V 2-Wire (1 hot, 1 neutral): In this case Line 1 passes though the tube marked L1. The piercing screw is used to pierce the wire insulation for L1 to provide the voltage reference to the meter.

The Neutral reference can either pass through the Tube marked L2 or it can be connected to the port marked N. If the neutral passes though the L2 tube then the piercing screw is used to pierce the wire insulation for to provide the neutral reference to the meter. State-of-the-art, fully solid-state kWh meter with 800 pulse per kWh pulse output.

0.5-1% accuracy dependent on setup (see above), LCD readout in hundredths of a kWh, to 99999.99 kWh. No conversion factor or multiplier. KWh data is maintained through power outages, and for up to 10 years without power.

Return within 30 days if you are not completely satisfied. Cool meter, good price and he got it here in a hurry. "Great value as described snap to install". "Easy to use just perfect thanks".

Great way to meter electricity for business use of home! Stands by his product and services. Was sent so fast it made my head spin. Perfect meter for billing rental customer.

"Meter arrived fast and safe, thanks". _gsrx_vers_1469 GS 9.1 (1469).